Dynamic Linear, Swell Meter , High Temperature Model DHSM-82,Measuring Units 2 head
HOME » PRODUCTS » DRILLING FLUIDS & OIL WELL » Shale Swell Meter / Shale Test » Dynamic Linear, Swell Meter , High Temperature Model DHSM-82,Measuring Units 2 head

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button

Dynamic Linear, Swell Meter , High Temperature Model DHSM-82,Measuring Units 2 head

The Dynamic Linear, Swell Meter , High Temperature helps determine shale hydration or dehydration by measuring the increase or decrease in length over time of reconstituted or intact shale core. 

Measuring Units 2 head,Measuring Range:0-20mm

Working Temperature:0-300℃(572℉)

Availability:
Quantity:
  • DHSM-87

  • RIGCHINA

  • 150-87

Dynamic Linear, Swell Meter , High Temperature, with Data Acquisition System and Compactor and Computer

Helps determine shale hydration or dehydration

Problems such as stuck pipe, tight hole, washout, and sloughing can be related to shale stability. Tests used to determine if a specific shale is likely to cause problems include the capillary suction time (CST) test and the linear-swell meter (LSM) test. CST test results show the inhibitive effects of various slats and their concentrations on the dispersion of a shale.

The Linear Swell Meter is designed to simultaneously test up to four drilling fluids (expandable to eight) on a representative shale sample for extended periods of time at temperatures up to 200°F.

The Linear Swell Meter (LSM) helps determine shale hydration or dehydration by measuring the increase or decrease in length over time of reconstituted or intact shale core. Together the LSM and Capillary Suction Time (CST) tests determine the recommended mud system for drilling through a specific shale formation. First, a CST test is conducted to determine the correct inhibitor for the shale. Then, a variety of fluids are tested.

Test results are graphed to show the percent of swelling versus swelling time in minutes. The LSM test demonstrates the inhibitive effects of these various fluids on shale swelling.

Most swell meters are designed to test shale samples in static fluid. However, fluids circulate as you drill, so testing shale samples in a static environment does not always provide accurate readings.

 

Dynamic Linear,   High Temperature Swell Meter W/Data Acquisition System

Part No.

Model

Description

150-87

DHSM-87

Measuring   Units 4 head

Stirring   Speed: 0-2500rpm

Working   Temperature:0-300℃ (572℉)

Measuring   Range:0-20mm

Accurancy:0.01mm

Sample   Diameter:28.6mm

Power supply:   220V, 50/60 Hz
Size:98*48*26cm (38.6*18.9*10.2in)
Weight:68kg (149.6lb)

150-82

DHSM-82

Measuring   Units 2 head

Stirring   Speed: 0-2500rpm

Working   Temperature: 0-300℃ (572℉)

Measuring   Range:0-20mm

Accurancy:0.01mm

Sample   Diameter:28.6mm

Power supply:   220V, 50/60 Hz

Size:98*48*26cm (38.6*18.9*10.2in)
Weight:18kg (40lb)