The Mud Cooler for Rheometer provides controlled sample cooling for a Viscometer. The circulating chiller is capable of regulated sample cooling; from ambient temperature to -20°C.
Retort 10ml Oil and Water Kit, with Electronic Temperature Control, Model RROW-10N Used to determine the quantity of liquids and solids in a drilling fluid with Electronic Temperature Control Sample Cup: 10 mL capacity Working Temperature: 930°F ± 70° F (516 ±22°C).
Retort 20ml Oil and Water Kit, with Electronic Temperature Control, Model RROW-20N Used to determine the quantity of liquids and solids in a drilling fluid with Electronic Temperature Control Sample Cup: 20 mL capacity Working Temperature: 930°F ± 70° F (516 ±22°C).
The Cementing Constant Speed Blender facilitates the preparation of oil well cements for testing according to the guidelines stated within API Specification 10.
The Lab Blender with 10 levels of variable speed, making easier for adjusting and choosing speed level. 10 Preset: 3800,7600,11400,15200,19000,22800,26600,30400,34200,38000 RPM 3 auto-timer program Variable Speeds Range: 0-38,000 RPM
The lubricity test is designed to simulate the torque and drag produced by a given drilling fluid down-hole. Measure the lubricating quality of drilling fluids Provide data to evaluate the type and quantity of lubricating additives that may be required
The electrical stability (ES) of an oil-based drilling fluid is related to the stability of the emulsion and oil-wetting capability. It conforms to the test procedure described in API Recommended Practice 13B-2. Output voltage range:0 to 2025 V ± 25 V peak to ground (1432 RMS) Breakdown peak output current :61 micro-amps (1.59mm)
Viscosity factor meter is used to measure and appraise the lubricity of drilling fluid and quality compatibleness of drilling fluid lubricant. The meter has the characters of reasonable structure, reliable work, high accuracy and good repetitiveness Turnover speed:5.5-6.5minutes/round Angle reading:Accuracy by number:0.5
The High-Pressure, High-Temperature (HPHT) Consistometer measures cement slurry viscosity or consistency under elevated pressure and temperature conditions. Maximum operating temperature of 600 ℉ (275℃) UNIT working pressure: 40,000psi (2750 kPa) Double cells
The HTHP Filter Press is designed to evaluate the filtration characteristics of drilling fluids, cement slurries, fracturing fluids, and completion fluids under elevated temperatures and pressures. Maximum Temperature : 500℉ (260℃) 500 ml Single Capped Sample Cell for Filter Paper