    Teflon Liner For Aging Cells
    Testing highly corrosive fluids at high temperatures and pressures can cause significant, permanent damage to typical stainless steel aging cells. The Teflon® Liner is designed to prevent corrosive damage while still providing the same results as a standard aging cell.
    RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
     
  • Add to Compare
    Aging Cell with Teflon Liner, 260mL, High Temperature, 600°
    The Aging Cell with Teflon Liner is a 500 ml, Type 316 / 304 stainless steel pressure vessel, certified for 600℉ (315℃) and 2500 psi (17,237 kPa)
    RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
     
  • Add to Compare
    Aging Cell, 316/304 SS, 260mL, High Temperature, 600°
    The Aging Cell with Teflon Liner is a 260 ml, Type 316 / 304 stainless steel pressure vessel, certified for 600℉ (315℃) and 2500 psi (17,237 kPa)
    RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
     
  • Add to Compare
    Aging Cell, 316/304 SS, 500mL, High Temperature, 600°
    The Aging Cell with Teflon Liner is a 500 ml, Type 316 / 304 stainless steel pressure vessel, certified for 600℉ (315℃) and 2500 psi (17,237 kPa)
    RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
     
  • Add to Compare
    Aging Cell with Teflon Liner, 500mL, High Temperature, 600°
    The Aging Cell with Teflon Liner is a 500 ml, Type 316 / 304 stainless steel pressure vessel, certified for 600℉ (315℃) and 2500 psi (17,237 kPa)
    RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
     
  • Add to Compare
    Portable Roller Oven Model RCRO-2
    Roller Ovens provide an excellent method of aging fluid samples for further analysis.
    Temperature Range:475℉ (246℃),Capacity 2 unit cells.
    Digital temperature controller and Protection against over-temperature.
    The primary tool for this aging is a roller oven.The time period needed to more fully develop properties in a drilling fluid varies from as little as several hours (usually 16 hours) to as long as several days. The aging can be done at either ambient or elevated temperatures.
  • Add to Compare
    Magnetic Stirrer Model MS-200
    The stirrer is ideal stir tool for laboratory uses.Adjustable heating temperature, stirring times and stirring speeds. Automatic hold setting temperature through incidental temperature probe. Maximum Stirring Volume: 2000mL , Stirring Speed: 0~2500rpm . Timer: 999 minutes 
  • Add to Compare
    Hot Plate Magnetic Stirrer Model MS-400
    These stirrers are ideal stir tool for laboratory uses.Adjustable heating temperature, stirring times and stirring speeds. Maximum Stirring Volume: 2000mL , Stirring Speed: 0~2500rpm , Timer: 999 minutes ,Temperature Range: up to 300℃ Automatic hold setting temperature through incidental temperature probe.
  • Add to Compare
    Mechanical Dynamometer Model GLG-02
    The Dynamometer has proven to have limitless versatility as a tension, traction and weight measuring instrument. It has been used for such diverse jobs as mounting cables for bridges; adjusting tension on guy wires; field testing chain, rope, wire—anything requiring precision force or tension measurement.
  • Add to Compare
    SPM Pump Speed Indicator
    The SPM Pump Speed Indicator System provides quick, easy-to-read pump speed measurements — information the mud pressure gauge does not deliver. The system includes the gauge and a generator that powers the system.
  • Add to Compare
    Dynamic HTHP Swell Meter,Model DHSM-2A ,Measuring Units 2 head
    The HTHP Swell Meter is designed to simultaneously test up to four drilling fluids (expandable to eight) on a representative shale sample for extended periods of time at temperatures up to 150℃(302°F). Measuring Units 2 head