Testing highly corrosive fluids at high temperatures and pressures can cause significant, permanent damage to typical stainless steel aging cells. The Teflon® Liner is designed to prevent corrosive damage while still providing the same results as a standard aging cell. RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
The Aging Cell with Teflon Liner is a 500 ml, Type 316 / 304 stainless steel pressure vessel, certified for 600℉ (315℃) and 2500 psi (17,237 kPa) RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
The Aging Cell with Teflon Liner is a 260 ml, Type 316 / 304 stainless steel pressure vessel, certified for 600℉ (315℃) and 2500 psi (17,237 kPa) RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
The Aging Cell with Teflon Liner is a 500 ml, Type 316 / 304 stainless steel pressure vessel, certified for 600℉ (315℃) and 2500 psi (17,237 kPa) RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
The Aging Cell with Teflon Liner is a 500 ml, Type 316 / 304 stainless steel pressure vessel, certified for 600℉ (315℃) and 2500 psi (17,237 kPa) RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
Roller Ovens provide an excellent method of aging fluid samples for further analysis. Temperature Range:475℉ (246℃),Capacity 2 unit cells. Digital temperature controller and Protection against over-temperature. The primary tool for this aging is a roller oven.The time period needed to more fully develop properties in a drilling fluid varies from as little as several hours (usually 16 hours) to as long as several days. The aging can be done at either ambient or elevated temperatures.
The stirrer is ideal stir tool for laboratory uses.Adjustable heating temperature, stirring times and stirring speeds. Automatic hold setting temperature through incidental temperature probe. Maximum Stirring Volume: 2000mL , Stirring Speed: 0~2500rpm . Timer: 999 minutes
These stirrers are ideal stir tool for laboratory uses.Adjustable heating temperature, stirring times and stirring speeds. Maximum Stirring Volume: 2000mL , Stirring Speed: 0~2500rpm , Timer: 999 minutes ,Temperature Range: up to 300℃ Automatic hold setting temperature through incidental temperature probe.
The Dynamometer has proven to have limitless versatility as a tension, traction and weight measuring instrument. It has been used for such diverse jobs as mounting cables for bridges; adjusting tension on guy wires; field testing chain, rope, wire—anything requiring precision force or tension measurement.
The SPM Pump Speed Indicator System provides quick, easy-to-read pump speed measurements — information the mud pressure gauge does not deliver. The system includes the gauge and a generator that powers the system.
The HTHP Swell Meter is designed to simultaneously test up to four drilling fluids (expandable to eight) on a representative shale sample for extended periods of time at temperatures up to 150℃(302°F). Measuring Units 2 head